200 'A' Scan memory with calibration and parameters
Weight
1.8 kg
The New Generation Premium Ultrasonic Flaw Detector Advanscan AS-414 combines EECI years of experience and commitment to customers to provide the best Flaw Detector In Its category by way of most advanced technology, convenience, uniqueness, affordability & technical options for ultrasonic applications in the market. The New Generation Ultrasonic Flaw Detector Model AS-414 incorporates the latest and most advanced Hardware & Software available in its unique friendly Interactive Architecture. The Hardware architecture includes Single Board Computer Circuitry for Best performance. The Software is based on the latest Windows platform with open architecture enabling it to upgrade and configure to any required applications. The Tunable Square pulsar offers best S:N ratio. The large, High definition LCD display provides unmatched. stable & clear A-Scan representation in all type of lighting conditions. The rugged. lightweight, ergonomical conditions. The rugged, lightweight, ergonomical design enables the operator to use in any environment conditions.
Display:
Viewing Area (HxW), diagonal: 115 x 95mm, 149mm
Pixel Density: 640 x 480
Display Type: TFT color LCD
Display Freeze: Current display freeze selectable.
Active Freeze: Display accumulation selectable.
Reference Pattern: Reference A scan pattern can be displayed at the Background from selected location in Memory.
Display Pattern: Unfilled or Filled.
Pulser:
Pulser: Tunable Square wave, selectable frequency. Single or up to 6 pulses in ''Burst'' mode
PRF: Variable 1000Hz. Auto limiting for set parameters
Pulse power: Hi/Lo selectable
Damping: 50E/1 K selectable
Receiver:
Receiver Bandwidth: 0.5 to 20MHz by wide band amplifier.
Digital Filter Setting: Selectable Low and High cut off frequency, in steps of 0.1 MHz. Adjustable between 0.1 MHz to 12 Mhz.
Gain: 0-120dB variable in 0.5dB step. Step size selectable decimal, unit or tens value
Rectification: Full wave/Positive Half wave/Negative Half wave, RF, selectable.
Horizontal Linearity: ±1%.
Rejection Amplitude: Linear type (0-99%), 1% step.
Measurement: 0 to 100% full screen.
Measurement rate: Equivalent to PRF in all modes
Vertical Linearity: ±3%
Calibration
Operating Mode: Single probe, Double probe, T-R mode
Test Mode: Pulse, reflection or Pulse Transmission
Units: Millimeters or Microseconds Selectable
Range: 5mm min.-tomtrs. Max @5890m/sec. Continuous variable in 1mm step. Step size selectable decimal, unit or tens value.